PSB Series Direct Mount Pressure Switch

The PSB Switch is a direct mount switch for critical pressure points. It has one limit contact that can be used to activate an alarm, actuate indicator lights or shutdown equipment. A glass-filled nylon terminal block with quick screw terminal connections gives the PSB switch a real advantage in industrial engine applications in general purpose non-classified areas. The PSB is ideal when a reading is not desired, but pressure is critical to operational efficiency.

PSB-75-F15: Direct Mount Pressure Switch
The PSB-75-F15 is a direct mount switch for critical pressure points. It has one limit contact that can be used to activate an alarm, actuate indicator lights or shutdown equipment. The trip point on this model is factory preset at 15 psi Falling, with a range of 0-75 psi.
Price:
PSB-100-F20: Direct Mount Pressure Switch
The PSB-100-F20 is a direct mount switch for critical pressure points. It has one limit contact that can be used to activate an alarm, actuate indicator lights or shutdown equipment. The trip point on this model is factory preset at 20 psi Falling, with a range of 0-100 psi.
Price:

Model PSB Direct Mount Pressure Switch

■ Limit Switch for Critical Pressure
■ Operate Alarms or Shutdown Equipment
■ SPDT Snap-Acting Switch
■ Fits Most Engine Applications

Description

The PSB switch is a direct mount switch for critical pressure points. It has one limit
contact that can be used to activate an alarm, actuate indicator lights or shutdown
equipment. The construction of this instrument is the same as our time-proven Swichgage.
instrument. A precision machined brass mounting plate and port captures a high
quality stamped beryllium copper diaphragm. The single-pole, double-throw
(SPDT) snap-switch is operated directly from the diaphragm for quick acting and
positive switching. Trip point is factory preset according to your specifications.

Housing is weather sealed to prevent entry of moisture, dust, etc. A glass-filled nylon
terminal block with quick screw terminal connections gives the PSB switch a real
advantage in industrial engine applications. The PSB is ideal when reading is not desired,
but pressure is critical to operational efficiency.

Intended for use in general purpose nonclassified areas.

Applications

. Engine Lubrication . Water pumps
. Compressors . Oil field systems
. Irrigation systems
. Construction Equipment
. Mobile Equipment
. Marine engines . Generators
Features

. Fits all engine applications
. SPDT snap-switch
. Activates indicator lights, alarms, or shut
down equipment
. Time-proven SWICHGAGE. construction
. Easy wiring terminal block
. Steel housing specially coated to resist
corrosion
. Factory preset to your specifications
Specifications

Housing: Plated steel.
Pressure Connection: 1/8-27 NPT, Brass.
Diaphragm: Formed beryllium copper (heat
treated).
Pulsation Dampener: Brass (it is removable
for cleaning).

Terminal Block: Three #4-40 screws.
Accuracy: Trip point: ±3% of full scale.
Switch reset differential: ±7% of full scale.

Repeatability: ±1% of full scale.
Contact Rating: SPDT 3 A @ 30 VDC
inductive.
Maximum Pressure: See Trip Point Chart
on reverse side.

Temperature Range:

Ambient= -40°F (-40°C) thru 150°F (66°C).
Process= -40°F (-40°C) thru 250°F (121°C).
Factory Trip Point Setting: See Trip Point
Chart (on back).
Pressure Range: Specify from 0-400 psi (0

2.76 MPa) [0- 27.58 bar]. See Trip Point
Chart on reverse side.
Contact: Operates on rising or falling
pressure (specify).
Shipping Weight: 8 oz. (0.25 kgs).
Shipping Dimensions: 3 x 2-3/4 x 2-3/4 in.
(76 x 70 x 70 mm).

NOTE: No customer replacement parts.

**Products covered by this bulletin comply with EMC Council directive 89/336/EEC
regarding electromagnetic compatibility except as noted.

PSB-9104B page 1 of 2


2-1/4 in.
(57 mm)
NO C NC
2-9/16 in.
(65 mm)
1/2 in. (13 mm)
Square wrench flats
1/8-27 NPT
2-1/32 in. Dia.
(52 mm)
Slot head terminal
screws (4-40, UNC-2A)
Dimensions Installation Instructions
Mounting
CAUTION: Use wrench on shank to tighten or loosen pressure
connection. DO NOT TWIST CASE, which will damage the unit and
void the warranty.
1. Before installing the PSB switch, apply sealant, such as Teflon tape,
to the threads (be sure sealant does not block the inlet orifice).
2. The PSB can be mounted in horizontal or vertical angles (do not
mount switch facing down).
3. Locate the unit in place and secure it by tightening
the 1/8-27 NPT fitting into the desired location (do not
overtighten). DO NOT TWIST CASE.
Trip Point Chart
Ranges available Factory setting* Maximum pressure
psi (kPa/MPa) [bar] psi (kPa) [bar] Falling psi (kPa) [bar]
0-15 (0-103) [0-1.03] 3 (21) [.21] 30 (207) [2.07]
0-30 (0-207) [0-2.07] 7 (48) [.48] 60 (414) [4.14]
0-50 (0-345) [0-3.45] 10 (69) [.69] 100 (0-689) [0-6.89]
0-75 (0-517) [0-5.17] 15 (103) [1.03] 150 (0-1.03) [0-10.34]
0-100 (0-689) [0-6.89] 20 (138) [1.38] 200 (0-1.38) [0-13.79]
0-150 (0-1.03) [0-10.34] 30 (207) [2.07] 300 (0-2.07) [0-20.70]
0-200 (0-1.38) [0-13.79] 50 (345) [3.45] 400 (0-2.76) [0-27.60]
0-300 (0-2.07) [0-20.70] 75 (517) [5.17] 500 (3.45) [34.50]
0-400 (0-2.76) [0-27.60] 150 (1.03) [10.34] 500 (3.45) [34.50]
*These points will be used if switch trip point is not specified.
WRONG
UPMountingAngle
Wiring
CAUTION: DISCONNECT Electrical power before wiring.
1. Switch contacts (below) are shown
with no pressure applied to the
PSB switch.
2. A spade (forked) terminal
is recommended for all
PSB switch connections.
3. Complete the wiring operation
making sure the voltage and
current requirements are within
the PSB switch electrical
rating (see the typical wiring
diagram at right).
Normally
Closed (N.C.)
Normally
Open (N.O.)
Common (C)
PSB – –
To order the PSB model use the diagram below.
Pressure Range
Specify maximum value
from chart above.
Switch Trip Point .
F = Factory set to trip on falling. Specify “F” and the set point value.
Example: PSB-100-F20.
R = Factory set to trip on rising, Specify “R” and the set point value.
For units of measure other than psi, specify the set point value
followed by unit of measure as follows:
B = Bar
K = kPa/MPa
M = kg/cm2
Example: PSB-7B-2B
.Switch set point value will be stated on label.
How to Order
2-1/4 in.
(57 mm)
NO C NC
2-9/16 in.
(65 mm)
1/2 in. (13 mm)
Square wrench flats
1/8-27 NPT
2-1/32 in. Dia.
(52 mm)
Slot head terminal
screws (4-40, UNC-2A)
Dimensions Installation Instructions
Mounting
CAUTION: Use wrench on shank to tighten or loosen pressure
connection. DO NOT TWIST CASE, which will damage the unit and
void the warranty.
1. Before installing the PSB switch, apply sealant, such as Teflon tape,
to the threads (be sure sealant does not block the inlet orifice).
2. The PSB can be mounted in horizontal or vertical angles (do not
mount switch facing down).
3. Locate the unit in place and secure it by tightening
the 1/8-27 NPT fitting into the desired location (do not
overtighten). DO NOT TWIST CASE.
Trip Point Chart
Ranges available Factory setting* Maximum pressure
psi (kPa/MPa) [bar] psi (kPa) [bar] Falling psi (kPa) [bar]
0-15 (0-103) [0-1.03] 3 (21) [.21] 30 (207) [2.07]
0-30 (0-207) [0-2.07] 7 (48) [.48] 60 (414) [4.14]
0-50 (0-345) [0-3.45] 10 (69) [.69] 100 (0-689) [0-6.89]
0-75 (0-517) [0-5.17] 15 (103) [1.03] 150 (0-1.03) [0-10.34]
0-100 (0-689) [0-6.89] 20 (138) [1.38] 200 (0-1.38) [0-13.79]
0-150 (0-1.03) [0-10.34] 30 (207) [2.07] 300 (0-2.07) [0-20.70]
0-200 (0-1.38) [0-13.79] 50 (345) [3.45] 400 (0-2.76) [0-27.60]
0-300 (0-2.07) [0-20.70] 75 (517) [5.17] 500 (3.45) [34.50]
0-400 (0-2.76) [0-27.60] 150 (1.03) [10.34] 500 (3.45) [34.50]
*These points will be used if switch trip point is not specified.
WRONG
UPMountingAngle
Wiring
CAUTION: DISCONNECT Electrical power before wiring.
1. Switch contacts (below) are shown
with no pressure applied to the
PSB switch.
2. A spade (forked) terminal
is recommended for all
PSB switch connections.
3. Complete the wiring operation
making sure the voltage and
current requirements are within
the PSB switch electrical
rating (see the typical wiring
diagram at right).
Normally
Closed (N.C.)
Normally
Open (N.O.)
Common (C)
PSB – –
To order the PSB model use the diagram below.
Pressure Range
Specify maximum value
from chart above.
Switch Trip Point .
F = Factory set to trip on falling. Specify “F” and the set point value.
Example: PSB-100-F20.
R = Factory set to trip on rising, Specify “R” and the set point value.
For units of measure other than psi, specify the set point value
followed by unit of measure as follows:
B = Bar
K = kPa/MPa
M = kg/cm2
Example: PSB-7B-2B
.Switch set point value will be stated on label.
How to Order
In order to consistently bring you the highest quality, full featured products, we reserve the right to change our
specifications and designs at any time. MURPHY, the Murphy logo are registered and/or common lawwww.fwmurphy.com trademarks of Murphy Industries, Inc. This document, including textual matter and illustrations, is copyright
918.317.4100 Email: sales@fwmurphy.com protected by Murphy Industries, Inc., with all rights reserved. (c) 2006 Murphy Industries, Inc.

Printed in U.S.A. 0591124M

In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications and designs at any time.

PSB-9104B

   


Alibaba Onlineshophttp://cnmec.en.alibaba.com

CNMEC Technology (Beijing) Co., Ltd.
Rm2115, T1-C Tower, Wangjing SOHO, Chaoyang District, Beijing China.
Tel:+86-10-8428 2935, 84278 3983; 8428 9077 Fax:+86-10-84288762
Wechat / Mobile phone:+86-10-13910962635
WeChat ID // a84282935
Website:http://www.zf83.cn
Email: sales@cnmec.biz



京ICP備08000916號
京公網安備11010502019740



主站蜘蛛池模板: 婷婷第四色| 日韩在线永久免费播放| 天美一二三传媒免费观看| 一女多男肉文| 日夜啪啪一区二区三区| 久久久久久噜噜噜久久久精品 | 99热99re| 国产免费人成在线视频视频| 在线播放一区二区精品产| 国产成年网站| 99热在线观看| 2021国产精品一卡2卡三卡4卡| 韩国视频在线观看高h| 日日躁夜夜躁狠狠久久AV| 精品国产乱码久久久久久下载| 久久国产情侣| 色-情-伦-理一区二区三区| 亚洲 日本 欧美 中文字幕| 日本黄色不卡视频| 99久久这里只精品国产免费| 国产色精品久久人妻无码 | 黄视频网站在线观看| 国产在线观看免费一级| 一个人免费完整在线观看日本| 色哦色哦哦色天天综合| 夜夜操狠狠干| 国产伊人久久| 做爰高潮A片在线播放| 中文乱码一线二线三线| 天天操一操| 国产精品久久久久久久午夜片| 日韩欧美高清一区| 亚洲一区精品在线| 五月婷婷激情网| 国产精品成人h视频| 日日摸天天添到高潮| 性妇WBBBB搡BBBB嗓小说| 夜夜夜精品视频免费| 久久久黄色大片| 韩国精品一区二区三区四区五区 | 天天拍夜夜操|